Application 1 · Industrial and OEM visual signaling

Industrial MicroLED

Status indication for equipment, lines, and facilities.

For OEMs, facilities, and industrial buyers who need a compact, sealed beacon that shows equipment or process state at a glance.

TOMAR MicroLED beacon with an amber lens, photographed against a white background

OEM equipment and machine status

Show machine or process status on OEM equipment and industrial automation systems.

Production and material handling

Provide visual notification on manufacturing lines, conveyors, and packaging machinery.

Utilities and process facilities

Provide compact visual indication in water and wastewater, chemical-processing, and oil and gas facilities.

Hazardous locations

Specify XL / HazLoc (Division 2) models for locations covered by the certification records.

Confirm the site's classification and the selected model before installation. View certifications

Application 2 · Traffic, ITS, and public-safety visual confirmation

Enforcement Light

A secondary view of the red signal.

Illustrative night view of a four-way intersection: both nearby signal heads face left together, so their red faces for cross traffic are hidden from the patrol officer, who sees the small blue TOMAR MicroLED indicator mounted atop the right signal head with a Sky Bracket mount.

At a signalized intersection, an officer positioned on a perpendicular approach may not be able to see the red signal facing cross traffic.

Mounted atop the signal head using a Sky Bracket mount, the blue MicroLED illuminates at the same time as the red signal—giving the officer a clear visual reference for identifying vehicles that enter the intersection against the light.

  • Red signal controls the vehicle approach
  • Blue MicroLED confirms the red phase to the officer
Use cases
  • Red-light enforcement
  • Traffic-signal state indication
  • Signal-preemption status indication
  • ITS and traffic-control cabinet indication

The Enforcement Light provides a visual indication for human observation. It does not independently detect violations or control the traffic signal.

Quoted on the 490 ½" female pipe mount, L / OrdLoc, in either voltage family and any of the six colors. Mounting Bracket Included.

Shared hardware · Specify the right fit

One platform. Four questions to answer.

Both applications share one hardware platform; ratings and options depend on the selected model. The Industrial MicroLED is offered in every mount and category shown here. Enforcement Light quotes use the 490 L / OrdLoc model in either voltage family and any of the six colors.

Supply

24 VAC/DC (±15%) or 120–240 VAC (±15%)

Low inrush: less than 1.75 A at 24 VDC and less than 2.0 A at 120 VAC

Indication

Flashing or steady-burn modes controlled by a third wire

6 output colors

Physical fit

470 surface, 490 ½" female pipe, or 495 ½" male thread mount

Compact 300-series MicroLED form and fit

Environment

NEMA 4X enclosure · Operating temperature: −50°C to +65°C

L / OrdLoc or XL / HazLoc (Division 2) category

Mounting

Loading…
470Surface Mount
Loading…
4901/2" Female Pipe Mount
Loading…
4951/2" Male Thread Mount

Output colors

Loading…
Amber / A
Loading…
Blue / B
Loading…
Green / G
Loading…
Purple / P
Loading…
Red / R
Loading…
White / W

Color selection should be based on the application, installation location, and applicable agency or jurisdiction requirements.

Product category

UL Certified · U.S. and Canada
L = OrdLoc

General-purpose Industrial configuration.

View certifications
UL Certified · U.S. and Canada
XL = HazLoc

Division 2 (HazLoc) configuration.

View certifications
Technical reference
Product description

The Industrial MicroLED is a compact LED signal beacon with the form and fit of TOMAR's existing 300-series MicroLED. The principal differences between the Industrial MicroLED and the existing MicroLED are AC-voltage capability, low-inrush circuitry, a wider range of colors, and selectable steady-burn or flashing operation controlled by a third wire.

Electrical performance
24 VAC/DC, 50/60 Hz
InputFlashingSteady burnPower
24 VAC190 mA120 mA5 W
24 VDC150 mA70 mA4 W
120–240 VAC, 50/60 Hz
InputFlashingSteady burnPower
120 VAC50 mA40 mA6.6 W
240 VAC45 mA30 mA12 W
Model numbers · 12 platform base configurations, 72 model numbers

Model numbers follow a fixed order: mount, product category, voltage, then color. The final character designates the color; "x" indicates the lens color in base-model notation. These are the full Industrial platform configurations; Enforcement Light selections are the 490L subset.

Base modelMountCategoryVoltage
470L-24-xSurface MountOrdLoc24 VAC/DC
490L-24-x1/2" Female Pipe MountOrdLoc24 VAC/DC
495L-24-x1/2" Male Thread MountOrdLoc24 VAC/DC
470L-120-240-xSurface MountOrdLoc120–240 VAC
490L-120-240-x1/2" Female Pipe MountOrdLoc120–240 VAC
495L-120-240-x1/2" Male Thread MountOrdLoc120–240 VAC
470XL-24-xSurface MountHazLoc24 VAC/DC
490XL-24-x1/2" Female Pipe MountHazLoc24 VAC/DC
495XL-24-x1/2" Male Thread MountHazLoc24 VAC/DC
470XL-120-240-xSurface MountHazLoc120–240 VAC
490XL-120-240-x1/2" Female Pipe MountHazLoc120–240 VAC
495XL-120-240-x1/2" Male Thread MountHazLoc120–240 VAC

Color codes: A = Amber · B = Blue · G = Green · P = Purple · R = Red · W = White

Industrial MicroLED certifications

UL certification for OrdLoc and HazLoc models.

UL Solutions Product iQ® records for the United States and Canada cover the Industrial MicroLED model families listed in each record. Enforcement Light quotes use 490L models, a family listed in the OrdLoc records; the HazLoc records do not apply to them.

Questions about certification?
Select · Install · Verify

Three steps from selection to verified installation.

  1. 1

    Confirm requirements

    Confirm the available supply (24 VAC/DC or 120–240 VAC) and the site and application requirements, including any hazardous-location classification.

  2. 2

    Choose the configuration

    Select the mount, product category, and color, and decide whether the application needs steady-burn or flashing indication.

  3. 3

    Install and verify

    Have a trained installer mount and wire the unit using the correct instructions and applicable codes, then test the system after installation.

Wiring
ConductorConnection
BlackLine voltage
WhiteNeutral
RED (steady-burn)Neutral or not connected
RED (flashing)Line
Installer requirements
  • Product must be installed by a trained installer
  • Installer must be familiar with the National Electrical Code and applicable local codes
  • Mounting location, controls, and wire routing should be directed by the facilities engineer
  • Read and understand all instructions before installation or operation
  • Do not connect the device while system power is on
  • Verify that the fixture nameplate matches the application
  • Deactivate the circuit before beginning installation
  • Install wiring in accordance with national and local codes
  • Tighten all screws and threaded joints after installation
  • Test the system after installation
  • Test the system regularly during service
  • Provide the instruction sheet to operating personnel after installation and testing
Mounting, operation, service, and cleaning

Mounting

  • The unit may be mounted in any orientation that provides the desired illumination.
  • Mounting hardware and final installation details are provided by the installer.

Nomenclature

  • The "x" in the model name indicates the lens color.

Operation

  • For operation, apply power.

Service

  • Verify that the proper voltage reaches the unit
  • Units are sealed
  • No field repairs are possible

Cleaning

  • Lens construction is Lexan polycarbonate
  • Use only mild soap and water
  • Do not use products containing hydrocarbons
Configure and request a quote

Build your configuration. Request a quote.

Step 1: build each model number. Step 2: review your quote list. Step 3: request a quote.

Build your quote

Choose application, mounting, category, voltage, and color, set a quantity, and add the configuration to your quote. Repeat for each configuration you need, then select Request a Quote.

Application
Mounting
Product category
Input voltage
Color
Loading…
470 Surface Mount · Amber lens
Model number
470L-24-A
List price: $193.77 each (USD)

Model format: {MOUNT}{CATEGORY}-{VOLTAGE}-{COLOR}. Final pricing, availability, freight, and tax confirmed in your quote.

Review your quote list

Edit or remove configurations, then continue to the quote form.

Your quote list is empty. Choose a configuration above and select Add to quote.
Resources

Flyers and documentation

Industrial MicroLED flyer
PUB0257

Industrial market flyer with product attributes and configuration guidance.

Download PDF
Enforcement Light flyer
PUB0256

Traffic and enforcement market flyer with product attributes.

Download PDF
Specifications, installation instructions, CAD files, and photography (on request)
  • Industrial MicroLED Product Specs

    Engineering marketing specifications dated 06-23-26.

    Available upon requestRequest by email
  • 24 VAC/DC HazLoc InstructionsIS1285-02

    Installation, operation, and maintenance data sheet for 24 VAC/DC HazLoc models.

    Available upon requestRequest by email
  • 120/240 VAC HazLoc InstructionsIS1286-03

    Installation, operation, and maintenance data sheet for 120/240 VAC HazLoc models.

    Available upon requestRequest by email
  • 24 VAC/DC OrdLoc InstructionsIS1287-02

    Installation, operation, and maintenance data sheet for 24 VAC/DC OrdLoc models.

    Available upon requestRequest by email
  • 120/240 VAC OrdLoc InstructionsIS1288-03

    Installation, operation, and maintenance data sheet for 120/240 VAC OrdLoc models.

    Available upon requestRequest by email
  • CAD / STEP files

    3D geometry for 470, 490 and 495 bases.

    Available upon requestRequest by email
  • Product photography

    High-resolution approved photography for all mounts and colors.

    Available upon requestRequest by email
  • Application guide

    Selection guidance across industrial and traffic applications.

    Available upon requestRequest by email

UL certificate PDFs for U.S. and Canada are in Certifications.

Get in touch

Get application support.

Need help with selection, documentation, or a distributor? Send an inquiry — OEM, distributor, and direct buyers are welcome. For pricing, use the quote list above.