Clear visual signaling. Configured for your application.
One platform. Two applications.
A compact LED signal beacon for industrial equipment and facilities, and an Enforcement Light for traffic-signal indication. Choose your application, then configure supply voltage, mount, category, and color.
- Voltage families
- 24 VAC/DC and 120–240 VAC
- Mounting options
- 470, 490, and 495
- Output colors
- Six
- Enclosure
- NEMA 4X

Industrial MicroLED
Status indication for equipment, lines, and facilities.
For OEMs, facilities, and industrial buyers who need a compact, sealed beacon that shows equipment or process state at a glance.

OEM equipment and machine status
Show machine or process status on OEM equipment and industrial automation systems.
Production and material handling
Provide visual notification on manufacturing lines, conveyors, and packaging machinery.
Utilities and process facilities
Provide compact visual indication in water and wastewater, chemical-processing, and oil and gas facilities.
Hazardous locations
Specify XL / HazLoc (Division 2) models for locations covered by the certification records.
Confirm the site's classification and the selected model before installation. View certifications
Enforcement Light
A secondary view of the red signal.

At a signalized intersection, an officer positioned on a perpendicular approach may not be able to see the red signal facing cross traffic.
Mounted atop the signal head using a Sky Bracket mount, the blue MicroLED illuminates at the same time as the red signal—giving the officer a clear visual reference for identifying vehicles that enter the intersection against the light.
- Red signal controls the vehicle approach
- Blue MicroLED confirms the red phase to the officer
- Red-light enforcement
- Traffic-signal state indication
- Signal-preemption status indication
- ITS and traffic-control cabinet indication
The Enforcement Light provides a visual indication for human observation. It does not independently detect violations or control the traffic signal.
Quoted on the 490 ½" female pipe mount, L / OrdLoc, in either voltage family and any of the six colors. Mounting Bracket Included.
One platform. Four questions to answer.
Both applications share one hardware platform; ratings and options depend on the selected model. The Industrial MicroLED is offered in every mount and category shown here. Enforcement Light quotes use the 490 L / OrdLoc model in either voltage family and any of the six colors.
24 VAC/DC (±15%) or 120–240 VAC (±15%)
Low inrush: less than 1.75 A at 24 VDC and less than 2.0 A at 120 VAC
Flashing or steady-burn modes controlled by a third wire
6 output colors
470 surface, 490 ½" female pipe, or 495 ½" male thread mount
Compact 300-series MicroLED form and fit
NEMA 4X enclosure · Operating temperature: −50°C to +65°C
L / OrdLoc or XL / HazLoc (Division 2) category
Mounting
Output colors
Color selection should be based on the application, installation location, and applicable agency or jurisdiction requirements.
Product category
General-purpose Industrial configuration.
View certificationsProduct description
The Industrial MicroLED is a compact LED signal beacon with the form and fit of TOMAR's existing 300-series MicroLED. The principal differences between the Industrial MicroLED and the existing MicroLED are AC-voltage capability, low-inrush circuitry, a wider range of colors, and selectable steady-burn or flashing operation controlled by a third wire.
Electrical performance
| Input | Flashing | Steady burn | Power |
|---|---|---|---|
| 24 VAC | 190 mA | 120 mA | 5 W |
| 24 VDC | 150 mA | 70 mA | 4 W |
| Input | Flashing | Steady burn | Power |
|---|---|---|---|
| 120 VAC | 50 mA | 40 mA | 6.6 W |
| 240 VAC | 45 mA | 30 mA | 12 W |
Model numbers · 12 platform base configurations, 72 model numbers
Model numbers follow a fixed order: mount, product category, voltage, then color. The final character designates the color; "x" indicates the lens color in base-model notation. These are the full Industrial platform configurations; Enforcement Light selections are the 490L subset.
| Base model | Mount | Category | Voltage |
|---|---|---|---|
| 470L-24-x | Surface Mount | OrdLoc | 24 VAC/DC |
| 490L-24-x | 1/2" Female Pipe Mount | OrdLoc | 24 VAC/DC |
| 495L-24-x | 1/2" Male Thread Mount | OrdLoc | 24 VAC/DC |
| 470L-120-240-x | Surface Mount | OrdLoc | 120–240 VAC |
| 490L-120-240-x | 1/2" Female Pipe Mount | OrdLoc | 120–240 VAC |
| 495L-120-240-x | 1/2" Male Thread Mount | OrdLoc | 120–240 VAC |
| 470XL-24-x | Surface Mount | HazLoc | 24 VAC/DC |
| 490XL-24-x | 1/2" Female Pipe Mount | HazLoc | 24 VAC/DC |
| 495XL-24-x | 1/2" Male Thread Mount | HazLoc | 24 VAC/DC |
| 470XL-120-240-x | Surface Mount | HazLoc | 120–240 VAC |
| 490XL-120-240-x | 1/2" Female Pipe Mount | HazLoc | 120–240 VAC |
| 495XL-120-240-x | 1/2" Male Thread Mount | HazLoc | 120–240 VAC |
Color codes: A = Amber · B = Blue · G = Green · P = Purple · R = Red · W = White
UL certification for OrdLoc and HazLoc models.
UL Solutions Product iQ® records for the United States and Canada cover the Industrial MicroLED model families listed in each record. Enforcement Light quotes use 490L models, a family listed in the OrdLoc records; the HazLoc records do not apply to them.
Ordinary Locations — OrdLoc
Industrial MicroLED L-series models are covered by separate UL Solutions records for the United States and Canada.
Record details and covered models
Visual-signal Appliances
- UL Category Code:
- UEES
- UL File No.:
- E210160
- Last Updated:
- June 25, 2026
Visual-signal Appliances Certified for Canada
- UL Category Code:
- UEES7
- UL File No.:
- E210160
- Last Updated:
- June 25, 2026
470L, 490L, and 495L models in 24 VAC/DC and 120–240 VAC configurations, with Amber, Blue, Green, Purple, Red, or White output.
The records identify a Type 4X enclosure rating, indoor or outdoor use, and additional listing as a Marine Visual Signal Device under UXUB.
Hazardous Locations — HazLoc
Industrial MicroLED XL-series models are covered by separate UL Solutions hazardous-location records for the United States and Canada.
Record details and covered models
Visual-signal Appliances for Use in Hazardous Locations
- UL Category Code:
- UJTK
- UL File No.:
- E537065
- Last Updated:
- July 2, 2026
Visual-signal Appliances for Use in Hazardous Locations Certified for Canada
- UL Category Code:
- UJTK7
- UL File No.:
- E537065
- Last Updated:
- July 2, 2026
Class I, Division 2, Groups A, B, C, and D; Class II, Division 2, Groups F and G.
4xx-series 470XL, 490XL, and 495XL models in 24 VAC/DC and 120–240 VAC configurations, with color suffixes A, B, W, G, R, or P.
Reprinted from Product iQ with permission from UL Solutions. ©2026 UL LLC.
Three steps from selection to verified installation.
- 1
Confirm requirements
Confirm the available supply (24 VAC/DC or 120–240 VAC) and the site and application requirements, including any hazardous-location classification.
- 2
Choose the configuration
Select the mount, product category, and color, and decide whether the application needs steady-burn or flashing indication.
- 3
Install and verify
Have a trained installer mount and wire the unit using the correct instructions and applicable codes, then test the system after installation.
Wiring
| Conductor | Connection |
|---|---|
| Black | Line voltage |
| White | Neutral |
| RED (steady-burn) | Neutral or not connected |
| RED (flashing) | Line |
Installer requirements
- Product must be installed by a trained installer
- Installer must be familiar with the National Electrical Code and applicable local codes
- Mounting location, controls, and wire routing should be directed by the facilities engineer
- Read and understand all instructions before installation or operation
- Do not connect the device while system power is on
- Verify that the fixture nameplate matches the application
- Deactivate the circuit before beginning installation
- Install wiring in accordance with national and local codes
- Tighten all screws and threaded joints after installation
- Test the system after installation
- Test the system regularly during service
- Provide the instruction sheet to operating personnel after installation and testing
Mounting, operation, service, and cleaning
Mounting
- The unit may be mounted in any orientation that provides the desired illumination.
- Mounting hardware and final installation details are provided by the installer.
Nomenclature
- The "x" in the model name indicates the lens color.
Operation
- For operation, apply power.
Service
- Verify that the proper voltage reaches the unit
- Units are sealed
- No field repairs are possible
Cleaning
- Lens construction is Lexan polycarbonate
- Use only mild soap and water
- Do not use products containing hydrocarbons
Build your configuration. Request a quote.
Step 1: build each model number. Step 2: review your quote list. Step 3: request a quote.
Build your quote
Choose application, mounting, category, voltage, and color, set a quantity, and add the configuration to your quote. Repeat for each configuration you need, then select Request a Quote.
Model format: {MOUNT}{CATEGORY}-{VOLTAGE}-{COLOR}. Final pricing, availability, freight, and tax confirmed in your quote.
Review your quote list
Edit or remove configurations, then continue to the quote form.
Flyers and documentation
Industrial market flyer with product attributes and configuration guidance.
Download PDFTraffic and enforcement market flyer with product attributes.
Download PDFSpecifications, installation instructions, CAD files, and photography (on request)
- Industrial MicroLED Product Specs
Engineering marketing specifications dated 06-23-26.
Available upon requestRequest by email - 24 VAC/DC HazLoc InstructionsIS1285-02
Installation, operation, and maintenance data sheet for 24 VAC/DC HazLoc models.
Available upon requestRequest by email - 120/240 VAC HazLoc InstructionsIS1286-03
Installation, operation, and maintenance data sheet for 120/240 VAC HazLoc models.
Available upon requestRequest by email - 24 VAC/DC OrdLoc InstructionsIS1287-02
Installation, operation, and maintenance data sheet for 24 VAC/DC OrdLoc models.
Available upon requestRequest by email - 120/240 VAC OrdLoc InstructionsIS1288-03
Installation, operation, and maintenance data sheet for 120/240 VAC OrdLoc models.
Available upon requestRequest by email - CAD / STEP files
3D geometry for 470, 490 and 495 bases.
Available upon requestRequest by email - Product photography
High-resolution approved photography for all mounts and colors.
Available upon requestRequest by email - Application guide
Selection guidance across industrial and traffic applications.
Available upon requestRequest by email
UL certificate PDFs for U.S. and Canada are in Certifications.
Get application support.
Need help with selection, documentation, or a distributor? Send an inquiry — OEM, distributor, and direct buyers are welcome. For pricing, use the quote list above.
Loading form…